Przeglądanie stron 169
Appendix C: BMC Sensor Tables Intel® Workstation Board S5520SC TPS
Revision 1.7
Intel order number: E39530-010
156
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Readin
g Type
Event Offset
Triggers
Contrib. To
System
Status
Assert/D
e-assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
IOH Thermal Margin
(IOH Therm Margin)
22h All
Temperature
01h
Threshold
01h
– – Analog
Processor 1 Memory
Thermal Margin
(Mem P1 Thrm Mrgn)
23h All
Temperature
01h
Threshold
01h
– – Analog
Processor 2 Memory
Thermal Margin
(Mem P2 Thrm Mrgn)
24h
Dual
processor
only
Temperature
01h
Threshold
01h
– – Analog
Fan Tachometer Sensors
(Chassis specific
sensor names)
30h–39h
Chassis-
specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal2
As and
De
Analog R, T M
Fan Present Sensors
(Fan x Present)
40h–45h
Chassis-
specific
Fan
04h
Generic
08h
01 - Device
inserted
OK
As and
De
-
Triggered
Offset
Auto –
Fan Redundancy
1
(Fan Redundancy)
46h
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully
redundant
OK
As and
De
– Trig Offset
A –
01 – Redundancy
lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-
redundant:
Sufficient
resources.
Transition from
redundant
Degraded