Intel S5000PAL Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Płyty główne do serwerów / stacji roboczych Intel S5000PAL. Intel S5000PAL User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Intel
®
Server Board S5000PAL
User’s Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number D31968-003
Przeglądanie stron 0
1 2 3 4 5 6 ... 79 80

Podsumowanie treści

Strona 1 - User’s Guide

Intel® Server Board S5000PAL User’s GuideA Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ProductsIntel Order Number D3

Strona 2

x Intel® Server Board S5000PAL User’s Guide

Strona 3 - Safety Information

Intel® Server Board S5000PAL User’s Guide xiContentsSafety Information ...

Strona 4 - 服务器主板与服务器机箱安全信息》)。

xii Intel® Server Board S5000PAL User’s GuideBefore You Begin ...

Strona 5 - Warnings

Intel® Server Board S5000PAL User’s Guide xiiiSystem Boots when Installing PCI Card ...

Strona 6

xiv Intel® Server Board S5000PAL User’s Guide

Strona 7 - Manual Organization

Intel® Server Board S5000PAL User’s Guide xvList of TablesTable 1. Additional Information and Software ...

Strona 8 - Product Accessories

xvi Intel® Server Board S5000PAL User’s Guide

Strona 9 - See also the Intel

Intel® Server Board S5000PAL User’s Guide xviiList of FiguresFigure 1. Intel® Server Board S5000PAL ...

Strona 10

xviii Intel® Server Board S5000PAL User’s Guide

Strona 11 - Contents

2 Server Board FeaturesThis chapter briefly describes the main features of the Intel® Server Board S5000PAL. This chapter provides a photograph of the

Strona 12

ii Intel® Server Board S5000PAL User’s GuideDisclaimer Information in this document is provided in connection with Intel® products. No license, expres

Strona 13 - Appendix E: Intel

2 Intel® Server Board S5000PAL User’s GuideTable 2 summarizes the features of the server board.Table 2. Server Board FeaturesFeature DescriptionProce

Strona 14

Intel® Server Board S5000PAL User’s Guide 3Connector and Component LocationsServer Management Intel® System Management SoftwareTable 2. Server Board

Strona 15 - List of Tables

4 Intel® Server Board S5000PAL User’s GuideFigure 2. Server Board Connector and Component LocationsA. BIOS Bank Select Jumper B. Intel® 6321ESB IO Con

Strona 16

Intel® Server Board S5000PAL User’s Guide 5Configuration JumpersFigure 3. BIOS Select JumperJumper Name Jumper PurposeBIOS Select If pins 1-2 are jump

Strona 17 - List of Figures

6 Intel® Server Board S5000PAL User’s GuideFigure 4. Recovery JumpersJumper Name Jumper PurposeCMOS Clear If pins 2-3 are jumpered, the CMOS settings

Strona 18

Intel® Server Board S5000PAL User’s Guide 7Intel® Light Guided DiagnosticsThe server board contains diagnostic LEDs to help you identify failed and fa

Strona 19 - 2 Server Board Features

8 Intel® Server Board S5000PAL User’s GuideBack Panel ConnectorsFigure 6. Back Panel ConnectorsA. Mouse B. KeyboardC. Serial Port B D. NIC 1 (10/100/1

Strona 20

Intel® Server Board S5000PAL User’s Guide 9The NIC LEDs at the right and left of each NIC provide the following information.RAID SupportThe Intel® Ser

Strona 21 - System Management Software

10 Intel® Server Board S5000PAL User’s GuideHardware RequirementsTo avoid integration difficulties and possible board damage, your system must meet th

Strona 22

Intel® Server Board S5000PAL User’s Guide 11MemoryThe server board provides eight DIMM sockets across two branches, and each branch has two channels.

Strona 23 - Configuration Jumpers

Safety InformationImportant Safety InstructionsRead all caution and safety statements in this document before performing any of the instructions. See

Strona 24 - Figure 4. Recovery Jumpers

12 Intel® Server Board S5000PAL User’s GuideFigure 8. Four DIMM Configuration ExampleIn non-mirrored mode, all DIMMs with the same slot number within

Strona 25 - Light Guided Diagnostics

Intel® Server Board S5000PAL User’s Guide 13Memory mirroring and memory sparing are mutually exclusive. Only one can be active at a time. See the Inte

Strona 26 - Back Panel Connectors

14 Intel® Server Board S5000PAL User’s GuideIntel® Local Control PanelThe Intel® Local Control Panel provides enhanced system control by utilizing a L

Strona 27 - RAID Support

3 Server UtilitiesUsing the BIOS Setup UtilityThis section describes the BIOS Setup Utility options, which is used to change server configuration defa

Strona 28 - Hardware Requirements

16 Intel® Server Board S5000PAL User’s Guide“Setup Menu Key Use” describes the keyboard commands you can use in the BIOS Setup menus. Table 4. Setup M

Strona 29

Intel® Server Board S5000PAL User’s Guide 17Upgrading the BIOSThe upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in

Strona 30 - Memory Sparing and Mirroring

18 Intel® Server Board S5000PAL User’s GuideObtaining the UpgradeDownload the BIOS image file to a temporary folder on your hard drive. See “Additiona

Strona 31 - Optional Hardware

Intel® Server Board S5000PAL User’s Guide 19Figure 9. Clear Password Jumper4. Wait five seconds.5. Return the Password Clear jumper to the Password Cl

Strona 32 - Local Control Panel

20 Intel® Server Board S5000PAL User’s GuideFigure 10. Clear CMOS Jumper4. Wait five seconds.5. Return the CMOS Clear jumper to the CMOS Clear by BMC

Strona 33 - 3 Server Utilities

4 Hardware Installations and UpgradesBefore You BeginBefore working with your server product, pay close attention to the “Safety Information” at the b

Strona 34 - Table 4. Setup Menu Key Use

iv Intel® Server Board S5000PAL User’s Guide重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-01077

Strona 35 - Upgrading the BIOS

22 “Intel® Server Board S5000PAL User’s Guide”Figure 11. Installing the Memory6. Make sure the clips at either end of the DIMM socket(s) are pushed ou

Strona 36 - Clearing the Password

“Intel® Server Board S5000PAL User’s Guide” 2311. Replace the server's cover and reconnect the AC power cord. See the documentation that came wit

Strona 37 - Clearing the CMOS

24 “Intel® Server Board S5000PAL User’s Guide”Installing the ProcessorTo install a processor, follow these instructions: 1. Observe the safety and ESD

Strona 38 - 20 Intel

“Intel® Server Board S5000PAL User’s Guide” 257. Line up the alignment marks on the processor and the socket, and insert the processor into the socket

Strona 39 - 4 Hardware Installations and

26 “Intel® Server Board S5000PAL User’s Guide”Installing the Heat Sink(s)The heat sink has Thermal Interface Material (TIM) located on the bottom of i

Strona 40 - 22 “Intel

“Intel® Server Board S5000PAL User’s Guide” 27Removing a Processor1. Observe the safety and ESD precautions in “Safety Information”.2. Turn off all pe

Strona 41 - Removing DIMMs

28 “Intel® Server Board S5000PAL User’s Guide”Replacing the Backup BatteryThe lithium battery on the server board powers the RTC for up to 10 years in

Strona 42 - Installing the Processor

“Intel® Server Board S5000PAL User’s Guide” 291. Observe the safety and ESD precautions in “Safety Information”.2. Turn off all peripheral devices con

Strona 43

30 “Intel® Server Board S5000PAL User’s Guide”

Strona 44 - Installing the Heat Sink(s)

Appendix A: Getting HelpWorld Wide Webhttp://support.intel.com/support/motherboards/server/S5000PAL.TelephoneAll calls are billed per incident, levied

Strona 45 - Removing a Processor

Intel® Server Board S5000PAL User’s Guide vWarningsHeed safety instructions: Before working with your server product, whether you are using this guide

Strona 46 - Replacing the Backup Battery

32 Intel® Server Board S5000PAL User’s GuideIn Asia-Pacific RegionAustralia... 1800 649931Cambodia.. 63 2 636 9797 (via Philippines)China... 80

Strona 47

Intel® Server Board S5000PAL User’s Guide 33Colombia... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481Costa Rica. Contact

Strona 48 - 30 “Intel

34 Intel® Server Board S5000PAL User’s Guide

Strona 49 - Appendix A: Getting Help

Appendix B: Regulatory and Compliance InformationProduct Regulatory ComplianceProduct Safety ComplianceThe Intel® Server Board S5000PAL complies with

Strona 50 - Latin America

36 Intel® Server Board S5000PAL User’s Guide• GOST R 50628-95 Immunity -Listed on one System License (Russia)• Belarus License - Listed on one System

Strona 51

Intel® Server Board S5000PAL User’s Guide 37Electromagnetic Compatibility NoticesFCC (USA)This device complies with Part 15 of the FCC Rules. Operatio

Strona 52 - 34 Intel

38 Intel® Server Board S5000PAL User’s Guide• Increase the separation between the equipment and the receiver.• Connect the equipment to an outlet on a

Strona 53 - Compliance Information

Intel® Server Board S5000PAL User’s Guide 39Korean Compliance (RRL)English translation of the notice above:1. Type of Equipment (Model Name): On Licen

Strona 54

40 Intel® Server Board S5000PAL User’s GuideRestriction of Hazardous Substances (RoHS) ComplianceIntel has a system in place to restrict the use of ba

Strona 55 - FCC (USA)

Appendix C: TroubleshootingThis chapter helps you identify and solve problems that might occur while you are using the system. For any issue, first en

Strona 56 - Industry Canada (ICES-003)

vi Intel® Server Board S5000PAL User’s Guide

Strona 57 - CNCA (CCC-China)

42 Intel® Server Board S5000PAL User’s GuideProblems following Initial System InstallationProblems that occur at initial system startup are usually ca

Strona 58 - Compliance

Intel® Server Board S5000PAL User’s Guide 43Hardware Diagnostic TestingThis section provides a more detailed approach to identifying a hardware proble

Strona 59 - Appendix C: Troubleshooting

44 Intel® Server Board S5000PAL User’s GuideSpecific Problems and Corrective ActionsThis section provides possible solutions for these specific proble

Strona 60 - First Steps Checklist

Intel® Server Board S5000PAL User’s Guide 45No Characters Appear on ScreenCheck the following:• Is the keyboard functioning? Test it by turning the &q

Strona 61 - Hardware Diagnostic Testing

46 Intel® Server Board S5000PAL User’s Guide• Does this video monitor work correctly if plugged into a different system?System Cooling Fans Do Not Rot

Strona 62 - Power Light Does Not Light

Intel® Server Board S5000PAL User’s Guide 47Cannot Connect to a Server• Make sure the network cable is securely attached to the correct connector at t

Strona 63

48 Intel® Server Board S5000PAL User’s Guide• The network driver files may be corrupt or deleted. Delete and then reinstall the drivers.• Run diagnost

Strona 64 - 46 Intel

Intel® Server Board S5000PAL User’s Guide 49• If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if keyboard input is

Strona 65 - Problems with Network

50 Intel® Server Board S5000PAL User’s GuideLED InformationThe Intel® Server Board S5000PAL includes LEDs that can aid in troubleshooting your system.

Strona 66 - 48 Intel

Intel® Server Board S5000PAL User’s Guide 51In addition to the beep codes above, additional beep codes are provided if an Intel® Remote Management Mod

Strona 67

PrefaceAbout this ManualThank you for purchasing and using the Intel® Server Board S5000PAL. This manual is written for system technicians who are res

Strona 68 - BIOS POST Beep Codes

52 Intel® Server Board S5000PAL User’s Guide

Strona 69

Appendix D: LED DecoderDuring the system boot process, BIOS executes a number of platform configuration processes, each of which is assigned a specifi

Strona 70 - 52 Intel

54 Intel® Server Board S5000PAL User’s GuideFigure 17. Diagnostic LED Placement DiagramLSB MSB Back edge of server board USB Port USB Port Diagnostic

Strona 71 - Appendix D: LED Decoder

Intel® Server Board S5000PAL User’s Guide 55PCI Bus0x50h OFF R OFF R Enumerating PCI busses0x51h OFF R OFF A Allocating resources to PCI busses0x52h O

Strona 72 - Diagnostic LEDs

56 Intel® Server Board S5000PAL User’s Guide0x93h R OFF G A Enabling the keyboard0x94h R G OFF R Clearing keyboard input buffer0x95h R G OFF A Instruc

Strona 73

Intel® Server Board S5000PAL User’s Guide 570XDA A R G R Trying boot device selection 0xDB A R G A Trying boot device selection 0xDC A A OFF R Trying

Strona 74

58 Intel® Server Board S5000PAL User’s Guide0xFAh A R A R Operating system has requested the system to reset (ResetSystem () has been called)Pre-EFI I

Strona 75

Appendix E: Intel® Server Issue Report FormNote: An on-line / automatic submission version of this form is available at http://support.intel.com/suppo

Strona 76

60 Intel® Server Board S5000PAL User’s GuideDIMM ConfigurationDIMM A1 MB and Vendor / part number:__________________________________DIMM A2 MB and Ven

Strona 77 - Server Issue Report

Intel® Server Board S5000PAL User’s Guide 61Hard Drive InformationManagement InformationOn-Board Platform Instrumentation only _______________________

Strona 78 - Operating System Information

viii Intel® Server Board S5000PAL User’s GuideProduct AccessoriesThis server board is compatible with the following Intel® Server Chassis:• Intel® Ser

Strona 79 - Control Panel Information

62 Intel® Server Board S5000PAL User’s GuideComplete Problem DescriptionIn the space below, provide a complete description of the steps used to reprod

Strona 80 - Complete Problem Description

Intel® Server Board S5000PAL User’s Guide ixSee also the Intel® Server Deployment Toolkit 2.0 CD that came with your server board.Accessories or other

Komentarze do niniejszej Instrukcji

Brak uwag