Intel® Server Board SE7320VP2
User Guide
Order Number: C71354-002
Przeglądanie stron 0
1 2 3 4 5 6 ... 56 57

Podsumowanie treści

Strona 1 - User Guide

Intel® Server Board SE7320VP2 User Guide Order Number: C71354-002

Strona 2

Preface x

Strona 3

Contents Contents 1 Server Board Features... 15 Connector and Header L

Strona 4

Contents Characters Are Distorted or Incorrect...43 System Cooling Fans Do Not

Strona 5 - Safety Information

Contents Tables Table 1. Server Board Features ... 16 Table 2. Recove

Strona 7 - Safety Cautions

1 Server Board Features This chapter briefly describes the main features of Intel® Server Board SE7320VP2. This chapter provides a photograph of the

Strona 8 - Consignes de sécurité

Server Board Features Table 1 summarizes the major features of the server board. Table 1. Server Board Features Feature Description Processors Supp

Strona 9 - AVVERTENZA: Italiano

Server Board Features Connector and Header Locations TP00941ABCEGHIJLKMRSXTVWZYAAPONFDCCQUBBA Serial Port A header K Processor 2 fan header U Co

Strona 10 - Preface

Server Board Features Configuration Jumpers Recovery Jumpers TP00942J1H2, J1H3, J1H532J1H2 Pass Clr3232J1H3 Rcvr BootJ1H5 CMOS ClrProtectEraseRecover

Strona 11 - Contents

Server Board Features Serial Port Configuration Jumper TP00944J8A33421-3: DCD to DTR (Default)2-4: DSR to DTR Figure 4. Serial Port Configuration Ju

Strona 12 - Figures

Disclaimer Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, t

Strona 13

Server Board Features BIOS Select Jumper TP00949J1A43BIOS Select1-2: Normal Operation (Default)2-3: Force toLower Bank3Figure 5. BIOS Select Jumper L

Strona 14

Server Board Features Back Panel Connectors TP00943AFC D E G HBA Mouse E NIC2 (1 Gb) B Keyboard F Video C Serial Port B G USB1 D NIC1 (1 Gb)

Strona 15 - 1 Server Board Features

Server Board Features Hardware Requirements To avoid integration difficulties and possible board damage, your system must meet the requirements outlin

Strona 16

Server Board Features DIMMs must meet the following requirements:  Use only DDR266 or DDR33, registered DDR DIMM modules  Use only DIMMs that com

Strona 17

Server Board Features For memory on-line sparing, one DIMM per channel is used as the memory spare. The spare DIMM is not available for use, but is ke

Strona 18 - Configuration Jumpers

2 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the Safety Information at the

Strona 19 - Server Board Features

Hardware Installations and Upgrades 4. Remove the server’s cover. See the documentation that accompanied your server chassis for instructions on remo

Strona 20 - BIOS Select Jumper

Hardware Installations and Upgrades Removing DIMMs To remove a DIMM, follow these steps: 1. Observe the safety and ESD precautions at the beginning

Strona 21 - Back Panel Connectors

Hardware Installations and Upgrades Installing or Replacing the Processor CAUTIONS Processor must be appropriate: You may damage the server board i

Strona 22 - Hardware Requirements

Hardware Installations and Upgrades 6. Align the pins of the processor with the socket, and insert the processor into the socket. ✏ NOTE Make sur

Strona 23 - Memory Sparing and Mirroring

Preface About this Manual Thank you for purchasing and using the Intel® Server Board SE7320VP2. This manual is written for system technicians who are

Strona 24 - ✏ NOTE

Hardware Installations and Upgrades Installing the Heat Sink(s) 1. The heat sink has Thermal Interface Material (TIM) located on the bottom of it. U

Strona 25 - Tools and Supplies Needed

Hardware Installations and Upgrades 8. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink again. Do not force

Strona 26 - Figure 7. Installing Memory

Hardware Installations and Upgrades Installing a PCI, PCI-X, or PCI-Express* Add-in Card Add-in cards are not included with your system and must be p

Strona 27 - Removing DIMMs

Hardware Installations and Upgrades VAROITUS Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan su

Strona 28 - Installing the Processor

3 Server Utilities Using the BIOS Setup Utility This section describes the BIOS Setup Utility options, which is used to change server configuration

Strona 29

Server Utilities Table 8. Keyboard Commands Press Description <F1> Help - Pressing F1 on any menu invokes the general Help window. The l

Strona 30 - Removing a Processor

Server Utilities Upgrading the BIOS The upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in the upgrade file include

Strona 31 - 2-4: DSR to DTR

Server Utilities Upgrading the BIOS Follow the instructions in the readme file that came with the BIOS upgrade. When the update completes, remove the

Strona 32 - VARNING

Server Utilities 4. Reconnect the AC power, power up the system. 5. Power down the system and disconnect the AC power. 6. Return the Password Clea

Strona 33 - VAROITUS

4 Troubleshooting This chapter helps you identify and solve problems that might occur while you are using the system. For any issue, first ensure y

Strona 34 - 3 Server Utilities

Preface Additional Information and Software If you need more information about this product or information about the accessories that can be used with

Strona 35 - Table 8. Keyboard Commands

Troubleshooting Problems following Initial System Installation Problems that occur at initial system startup are usually caused by an incorrect insta

Strona 36 - Upgrading the BIOS

Troubleshooting Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source.

Strona 37 - Clearing the Password

Troubleshooting Specific Problems and Corrective Actions This section provides possible solutions for these specific problems:  Power light does no

Strona 38 - Clearing the CMOS

Troubleshooting No Characters Appear on Screen Check the following:  Is the keyboard functioning? Test it by turning the “Num Lock” function on an

Strona 39 - 4 Troubleshooting

Troubleshooting System Cooling Fans Do Not Rotate Properly If the system cooling fans are not operating properly, it is an indication of possible syst

Strona 40 - First Steps Checklist

Troubleshooting CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light Check the following:  Are the CD-ROM/DVD-ROM drive’s power and signal c

Strona 41 - Hardware Diagnostic Testing

Troubleshooting The add-in adapter stopped working without apparent cause.  Try reseating the adapter first; then try a different slot if necessary

Strona 42 - Power Light Does Not Light

Troubleshooting  If you suspect that a transient voltage spike, power outage, or brownout might have occurred, reload the software and try running i

Strona 43 - Troubleshooting

Troubleshooting LED Information The Intel® Server Board SE7320VP2 includes LEDs that can aid in troubleshooting your system. A table of these LEDs wit

Strona 44

Regulatory and Compliance Information Product Regulatory Compliance Product Safety Compliance The Server Board SE7320VP2-E complies with the following

Strona 45 - Problems with Network

Preface Safety Information WARNING Before working with your server product, whether you are using this guide or any other resource as a reference, pa

Strona 46

Regulatory and Compliance Information Certifications / Registrations / Declarations  UL Certification (US/Canada)  CE Declaration of Conformity

Strona 47 - Operating System)

Regulatory and Compliance Information Electromagnetic Compatibility Notices FCC (USA) This device complies with Part 15 of the FCC Rules. Operation

Strona 48 - LED Information

Regulatory and Compliance Information Industry Canada (ICES-003) Cet appareil numérique respecte les limites bruits radioélectriques applicables aux

Strona 49 - Product Safety Compliance

Getting Help World Wide Web http://support.intel.com/support/motherboards/server/SE7320VP2 Telephone All calls are billed US $25.00 per incident, levi

Strona 50 - CANADA NMB-003 CLASSE A

Getting Help In Latin America Brazil 001-916 377 0180 Mexico Contact AT&T USA at 001 800 462 628 4240. Once connected, dial 800 843 4481 Col

Strona 51 - FCC (USA)

Intel® Server Issue Report Form ✏ NOTE An on-line / automatic submission version of this form is available at http://support.intel.com/support/mothe

Strona 52 - Korean Compliance (RRL)

Issue Report Form Operating System Information Operating System Version Service Pack Peripheral Information Check each box below that is us

Strona 53 - Getting Help

Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description

Strona 54

Preface Warnings System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC

Strona 55 - Server Issue Report Form

Preface Safety Cautions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boar

Strona 56 - Control Panel Information:

Preface 重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。参见 Resource CD(资源光盘) 和/或 http://support.intel.com/support/motherboards/server/ 上的 Intel Server Boards and

Strona 57

Preface Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera d

Komentarze do niniejszej Instrukcji

Chrishot 28 Apr 2024 | 12:54:15

Hello, im noob :)