Case Temperature Reference Metrology
94 Thermal and Mechanical Design Guidelines
14. Using a fine point device, place a small amount of flux on the thermocouple bead.
Be careful not to move the thermocouple bead during this step (Figure 7-24).
Ensure the flux remains in the bead area only.
Figure 7-24. Applying Flux to the Thermocouple Bead
15. Cut two small pieces of solder 1/16 inch (0.065 inch / 1.5 mm) from the roll using
tweezers to hold the solder while cutting with a fine blade (Figure 7-25).
Figure 7-25. Cutting Solder