Intel SSD DC P3600 Series will also support the following vendor unique SET Features.
Set/Get Max LBA (Feature Identifier C1h)
Set/Get Native Max LBA (Feature Identifier C2h)
Power Governor Setting (Feature Identifier C6h)
Reset Timed Workload Counters (Feature Identifier D5h)
Table 22: Set Max LBA Setting - Command Dword 11 and Command Dword 12
Maximum User LBA: Write Usage: This field sets the 64-bit maximum LBA addressable by
the Drive.
Read Usage: This field contains the 64-bit maximum LBA addressable by the Drive.
Command Dword 11 contains bits 31:00; Command Dword 12 contains bits 63: 32.
Table 23: Status Code - Set Max LBA Command Specific Status Values
Requested MAX LBA exceeds Available capacity
Requested MAX LBA smaller than minimum allowable limit.
Requested MAX LBA is smaller than allocated Namespace requirements
Table 24: C6h - Set/ Get Power Governor Setting – Command Dword 11
Power Governor Setting: 00h = 25W (typ), 01h = 20W (typ), 02h = 10W (typ)
Table 25: Status Codes - Power Governor Setting Command Specific Status Values
Table 26: D5h – Reset Timed Workload Counters – Command Dword 11
Timed Workload Reset Settings: Write Usage: 00 = NOP, 1 = Reset E2, E3,E4 counters; Read
Usage: Not Supported
Note: Get Features will not work for “Reset Timed Workload Counters” and status code is same as Table 25.
§