Intel S5000PSL Instrukcja Użytkownika Strona 105

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 120
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 104
Appendix B: BMC Sensor Tables Intel® Server Boards S5000PSL and S5000XSL TPS
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type Event /
Reading
Type
Event Offset
Triggers
Criticality Assert /
De-assert
Readable
Value /
Offsets
Event Data Rearm Standby
CPU
Population
Error
D8h All Processor
07h
Generic
03h
01h –- State
asserted
Critical As and De R, T A
Fault status
asserted
Degraded
Device installed OK
Disabled Degraded
DIMM A1 E0h All Slot
Connector
21h
Sensor
Specific
6Fh
Sparing OK
As – Trig Offset A
Fault status
asserted
Degraded
Device installed OK
Disabled Degraded
DIMM A2 E1h All Slot
Connector
21h
Sensor
Specific
6Fh
Sparing OK
As – Trig Offset A
Fault status
asserted
Degraded
Device installed OK
Disabled Degraded
DIMM B1 E2h All Slot
Connector
21h
Sensor
Specific
6Fh
Sparing OK
As – Trig Offset A
Fault status
asserted
Degraded
Device installed OK
Disabled Degraded
DIMM B2 E3h All Slot
Connector
21h
Sensor
Specific
6Fh
Sparing OK
As – Trig Offset A
Fault status
asserted
Degraded
Device installed OK
Disabled Degraded
DIMM C1 E4h All Slot
Connector
21h
Sensor
Specific
6Fh
Sparing OK
As – Trig Offset A
Fault status
asserted
Degraded
Device installed OK
DIMM C2 E5h All Slot
Connector
21h
Sensor
Specific
6Fh
Disabled Degraded
As – Trig Offset A
Revision 1.2
Intel order number: D41763-003
106
Przeglądanie stron 104