
Power Subsystem Intel® Server System SR1600UR TPS
20 Intel order number E45725-010 Revision 1.8
3.3 Efficiency
The following table provides the required minimum efficiency level at various loading conditions.
These are provided at three different load levels: 100%, 50% and 20%.
Efficiency is tested over
an AC input voltage range of 115 VAC to 220 VAC.
Table 13. Efficiency
100% of maximum 50% of maximum 20% of maximum
>80% >80% >80%
3.4 AC Input Voltage Requirement
The power supply must operate within all specified limits over the input voltage range shown in
the following table.
Table 14. AC Input Rating
Maximum
Rated Input
AC Current
rms
rms
rms
+/- 4 VAC
+/-5 VAC
9.5 A
rms
1,3
8.55 A
rms
4
rms
rms
rms
A
rms
2,3
4.3 A
rms
4
Notes:
1. Maximum input current at low input voltage range is measured at 90 VAC, at maximum load.
2. Maximum input current at high input voltage range is measured at 180 VAC, at maximum load.
3. This is not to be used for determining agency input current markings.
4. Maximum rated input current is measured at 100 VAC and 200 VAC.
Harmonic distortion of up to 10% THD must not cause the power supply to go out of specified
limits.
The power supply powers off if the AC input is less than 75 VAC +/-5 VAC range.
The
power supply starts up if the AC input is greater than 85 VAC +/- 4 VAC.
Application of an input
voltage below 85 VAC does not cause damage to the power supply, including a fuse blow.
3.5 Protection Circuits
Protection circuits inside the power supply cause only the power supply’s main outputs to shut
down.
If the power supply latches off due to a protection circuit tripping, an AC cycle OFF for 15
seconds and a PSON
#
cycle HIGH for one second reset the power supply.
Komentarze do niniejszej Instrukcji