Podsumowanie treści

Strona 1 - User Guide

Intel® Server Chassis SR1450 User Guide Order Number: C95452-002

Strona 2

Intel® Server Chassis SR1450 User Guide x Contents Warnings ...

Strona 3 - Preface

Contents Intel® Server Chassis SR1450 User Guide xi Installing a PCI Add-in Card...

Strona 4

Contents xii Extent of Limited Warranty...85 Warranty

Strona 5

Contents Intel® Server Chassis SR1450 User Guide xiii Figure 41. Removing the Power Supply Air Duct...

Strona 6

Intel® Server Chassis SR1450 User Guide 14 1 Server Chassis Features This chapter briefly describes the main features of Intel® Server Chassis SR14

Strona 7 - Safety Information

Server Chassis Features Intel® Server Chassis SR1450 User Guide 15 Table 1 summarizes the major features of the server chassis. 4 Table 1. Server C

Strona 8 - Warnings

Server Chassis Features 16 Table 1. Server Chassis Features (continued) Power Supply  One hot-swap 520W power supply module  One plus one hot-sw

Strona 9 - Consignes de sécurité

Server Chassis Features Intel® Server Chassis SR1450 User Guide 17 Component Identification Internal Components The diagram below shows the server ch

Strona 10 - Contents

Server Chassis Features 18 Standard Control Panel The diagram below shows the features available on the Standard Control Panel. The Standard Control

Strona 11

Server Chassis Features Intel® Server Chassis SR1450 User Guide 19 Intel® Local Control Panel The diagram below shows the features available on the I

Strona 12 - Figures

Disclaimer Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, t

Strona 13

Server Chassis Features 20 Callout Feature Function J System Status LED Solid green indicates normal operation. Blinking green indicates degraded p

Strona 14 - 1 Server Chassis Features

Server Chassis Features Intel® Server Chassis SR1450 User Guide 21 Peripheral Devices (Front Features) The chassis provides locations and hardware fo

Strona 15 -

Server Chassis Features 22 Floppy / CD-ROM / DVD-ROM Slimline Carriers The slimline drive carriers can be used with one slimline floppy, CD-ROM or D

Strona 16

Server Chassis Features Intel® Server Chassis SR1450 User Guide 23 Rack-Mounted Systems Your Intel® Server Chassis SR1450 is designed to be mounted

Strona 17 - Component Identification

Intel® Server Chassis SR1450 User Guide 24 2 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay clo

Strona 18 - Standard Control Panel

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 25 Removing and Installing the Chassis Cover Removing the Chassis Cove

Strona 19 - ✏ NOTE

Hardware Installations and Upgrades 26 Installing the Chassis Cover 1. Place the cover over the chassis so that the side edges of the cover sit just

Strona 20

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 27 Removing and Installing the Front Bezel The front bezels are availab

Strona 21 - ✏ NOTES

Hardware Installations and Upgrades 28 Installing the Front Bezel Use the steps below if your system includes either the standard front bezel or the f

Strona 22

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 29 Removing the Processor Air Duct 1. Observe the safety and ESD prec

Strona 23 - Front Bezels

Intel® Server Chassis SR1450 User Guide iii Preface About this Manual Thank you for purchasing and using the Intel® Server Chassis SR1450. This ma

Strona 24 - Before You Begin

Hardware Installations and Upgrades 30 TP01597 Figure 14. Preparing the Processor Air Duct 5. Place the processor air duct over the processor sock

Strona 25

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 31 Installing and Removing a Hard Disk Drive Up to three hard drives o

Strona 26 - Installing the Chassis Cover

Hardware Installations and Upgrades 32 4. Remove the four screws that attach the plastic baffle or the previously installed hard drive to the drive c

Strona 27 - Removing the Front Bezel

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 33 6. When the black drive carrier lever begins to close by itself, pu

Strona 28 - Installing the Front Bezel

Hardware Installations and Upgrades 34 Installing a Floppy Drive into Slimline Bay Use these instructions if you are installing a floppy drive into th

Strona 29

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 35 7. Open the connector on the rear of the floppy drive by pulling up

Strona 30

Hardware Installations and Upgrades 36 13. Connect the floppy drive data cable that was included with your kit between the interposer board and the

Strona 31

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 37 14. Install the chassis cover. For instructions, see “Installing th

Strona 32

Hardware Installations and Upgrades 38 7. Slide the floppy drive into the drive carrier, rear of the drive first, with the underside of the drive fac

Strona 33 - Standard)

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 39 10. Reattach the slide rails onto floppy drive conversion kit carri

Strona 34

Preface iv Product Contents, Order Options, and Accessories The server chassis SR1450 is compatible with the Intel® Server Board SE7520JR2. Your Ser

Strona 35

Hardware Installations and Upgrades 40 14. Attach the other end of the flat flex cable to the interposer board. 15. Install the interposer board in

Strona 36

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 41 Installing or Removing a CD-ROM or DVD-ROM Drive CAUTION CD-ROM an

Strona 37

Hardware Installations and Upgrades 42 9. Slide the DVD-ROM / CD-ROM drive carrier into the chassis. See letter “A” in the figure below. 10. Attach

Strona 38

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 43 Removing a CD-ROM or DVD-ROM Drive from the Slimline Bay 1. Observ

Strona 39

Hardware Installations and Upgrades 44 Installing a PCI Riser Card To install the PCI riser card, use the following instructions. 1. Observe the sa

Strona 40

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 45 6. Line up the stand-offs on the riser assembly with the slot and

Strona 41

Hardware Installations and Upgrades 46 Removing a PCI Riser Card The PCI riser card can be replaced if it fails or if a different option is required.

Strona 42

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 47 Installing and Removing a PCI Add-in Card Installing a PCI Add-in C

Strona 43 - CAUTION

Hardware Installations and Upgrades 48 6. Open the PCI retention clip on the PCI riser card assembly. See letter “A” in the figure below. 7. Remove

Strona 44 - Installing a PCI Riser Card

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 49 Removing a PCI Add-in Card 1. Observe the safety and ESD precaution

Strona 45

Preface Intel® Server Chassis SR1450 User Guide v You must choose from several required options when purchasing this chassis:  Riser option, choos

Strona 46

Hardware Installations and Upgrades 50 Replacing the Standard Control Panel Your server must be operated with a control panel installed. The steps fo

Strona 47 - Installing a PCI Add-in Card

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 51 Replacing the Intel® Local Control Panel Your server must be operate

Strona 48

Hardware Installations and Upgrades 52 8. If using a bezel with the Local Control Panel, change out the LCP plastic front panel on the replacement co

Strona 49 - Removing a PCI Add-in Card

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 53 Replacing System Fan(s) The system fans at the front of the Server

Strona 50

Hardware Installations and Upgrades 54 8. Note the position of the raised arrows in the top of the replacement fan. Position the fan so one arrow poi

Strona 51 - Local Control Panel

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 55 TP01626AB Figure 40. Removing the Single System PCI Fan 6. Note th

Strona 52

Hardware Installations and Upgrades 56 Removing the Power Supply Air Duct Use the steps below to remove the power supply air duct. 1. Observe the sa

Strona 53 - Replacing System Fan(s)

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 57 Replacing a Power Supply Fan Module The power supply fan modules in

Strona 54

Hardware Installations and Upgrades 58 Replacing the Power Distribution Board The power distribution board is located between the two power supplies.

Strona 55

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 59 TP01629LKHGGFJIACBEKDQP Figure 43. Removing the Power Distribution

Strona 56

Preface vi Additional Information and Software If you need more information about this product or information about the accessories that can be used w

Strona 57

Hardware Installations and Upgrades 60 23. If a slimline DVD/CD-ROM or floppy drive is installed, connect power (see letter “J” in “Figure 44”) and d

Strona 58

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 61 Replacing the Hot-Swap Power Supply The power supply can be replaced

Strona 59

Hardware Installations and Upgrades 62 TP01630BA Figure 46. Removing the Rear Hot-Swap Power Supply from the Chassis Installing a Hot-Swap Power Su

Strona 60

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 63 Removing and Installing the SATA or SCSI Backplane Your server chass

Strona 61

Hardware Installations and Upgrades 64 Removing the SATA or SCSI Backplane 1. Observe the safety and ESD precautions at the beginning of this book. S

Strona 62

Hardware Installations and Upgrades Intel® Server Chassis SR1450 User Guide 65 Installing the SATA or SCSI Backplane 1. Observe the safety and ESD

Strona 63

Hardware Installations and Upgrades 66 8. Connect the following cables to the backplane:  Front panel cable  Power cable  (SCSI backplane only

Strona 64

Intel® Server Chassis SR1450 User Guide 67 Technical Reference Cable Routing When you add or remove components from your server chassis, make sure

Strona 65

Technical Reference 68 TP01612BCDAE Figure 50. SATA Cable Routing Through Notches in Metal Air Baffle Table 3. SATA Cable Routing Reference A SATA0

Strona 66

Technical Reference Intel® Server Chassis SR1450 User Guide 69 Power Supply Specifications 520-W Single Power Supply Input Voltages  100-127 V∼

Strona 67 - Technical Reference

Preface Intel® Server Chassis SR1450 User Guide vii Safety Information WARNING Before working with your server product, whether you are using this

Strona 68

Technical Reference 70 System Environmental Specifications Table 5. Environmental Specifications Temperature Non-operating Operating –40 ° to 70 °

Strona 69 - Power Supply Specifications

Intel® Server Chassis SR1450 User Guide 71 Equipment Log and Worksheets Equipment Log Use this equipment log to record information about your serve

Strona 70

Equipment Log and Worksheets 72 Current Usage Calculating Power Usage The total combined wattage for your configuration must be less than the wattage

Strona 71 - Equipment Log and Worksheets

Equipment Log and Worksheets Intel® Server Chassis SR1450 User Guide 73 Worksheet, Total Combined Power Used by the Server 1. From the previous w

Strona 72

Intel® Server Chassis SR1450 User Guide 74 Regulatory and Compliance Information Product Regulatory Compliance Product Safety Compliance The Server

Strona 73

Regulatory and Compliance Information Intel® Server Chassis SR1450 User Guide 75 Certifications / Registrations / Declarations  UL Certification

Strona 74 - Product Safety Compliance

Regulatory and Compliance Information 76 Table 8. Product Certification Markings (continued) Regulatory Compliance Country Marking BSMI Certificati

Strona 75

Regulatory and Compliance Information Intel® Server Chassis SR1450 User Guide 77 This equipment has been tested and found to comply with the limits

Strona 76 - FCC (USA)

Regulatory and Compliance Information 78 VCCI (Japan) English translation of the notice above: This is a Class A product based on the standard of th

Strona 77 - Industry Canada (ICES-003)

Regulatory and Compliance Information Intel® Server Chassis SR1450 User Guide 79 Regulated Specified Components To maintain the UL listing and comp

Strona 78 - Korean RRL Compliance

Preface viii Warnings System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug th

Strona 79

Getting Help World Wide Web http://support.intel.com/support/motherboards/server/SR1450 Telephone All calls are billed US $25.00 per incident, levie

Strona 80 - Getting Help

Intel Server Issue Report Form Intel® Server Chassis SR1450 User Guide Intel® Server Issue Report Form Date Submitted: Company Name: Contact

Strona 81 - Server Issue Report Form

Operating System Information Operating System Version Service Pack # Peripheral Information Check each box below that is used, and provide

Strona 82 - Hard Drive Information:

Intel Server Issue Report Form Intel® Server Chassis SR1450 User Guide Complete Problem Description In the space below, provide a complete description

Strona 84

Intel® Server Chassis SR1450 User Guide 85 Warranty Limited Warranty for Intel® Chassis Subassembly Products Intel warrants that the Products (de

Strona 85 - Warranty

Warranty Warranty Limitations and Exclusions These warranties replace all other warranties, expressed or implied including, but not limited to, the i

Strona 86 - Limitations of Liability

Warranty Intel® Server Chassis SR1450 User Guide 87 How to Obtain Warranty Service To obtain warranty service for this Product, you may contact Int

Strona 87 - Telephone Support

Preface Intel® Server Chassis SR1450 User Guide ix Safety Cautions Read all caution and safety statements in this document before performing any of